**Symptoms this page covers:** Both compartments drifting warm together over a period of weeks; The compressor running continuously and never cycling off; Partial cooling that gets worse on hot days and recovers overnight; Frost on only one section of the evaporator rather than across it; A unit that was recharged elsewhere and has slowly warmed again; Unusual heat at the grille with very little cold in the cabinet.

**What the visit includes:** Full elimination of airflow, defrost and control faults before any cutting; Leak location rather than a top-up that puts the same fault back in service; Written estimate, and an honest view on whether the repair is worth doing; Recovery and recharge by EPA Section 608 certified technicians; 90 days on labour, 365 days on parts.

The sealed system is the closed refrigerant loop: compressor, condenser,
metering device, evaporator and the tubing that joins them. It is called sealed
because it is meant never to be opened, and opening it is the difference
between a service call and a genuine repair. It requires recovery equipment, a
proper vacuum, accurate charging by weight and EPA Section 608 certified
technicians, because releasing refrigerant is not a matter of preference.

Most of the work on this page is the work of proving that a sealed-system
repair is actually necessary.

## Almost everything that looks like a leak is not one

A warm cabinet has a short list of causes and the sealed system is at the
bottom of it, not the top. Ahead of it sit a corroded or restricted condenser,
a condenser fan that has slowed or stalls once it is hot, an evaporator fan
that has failed, a defrost cycle that terminates before the coil is clear, a
blocked drain that has iced the trough, door seals that are letting humid
kitchen air in, and a control fault that is asking for the wrong thing.

Every one of those is cheaper. Several of them are more common in Ponte Vedra
Beach than anywhere inland, because the condenser here corrodes on a coastal
schedule rather than a national one. A shop that reaches for refrigerant early
will make a sealed-system-sized invoice out of a fin pack full of salt, and the
unit will be warm again by the following summer.

So the order is fixed: eliminate air, defrost and control faults first, with
readings written down, and only then treat the sealed system as the remaining
explanation.

## Reading the system

Once the rest is ruled out, the pattern of the failure tells you a good deal.
A slow, even loss of capacity across both compartments over months suggests a
leak. Frost on only the first portion of the evaporator suggests a restriction
or an undercharge rather than a compressor that has stopped pumping. A unit
that cools acceptably overnight and fails every hot afternoon is short of
capacity margin, which can be a partial charge or a condenser that cannot
reject heat. Heat at the grille with no cold in the cabinet points at a
compressor running without pumping.

None of that is a diagnosis on its own. It is what shapes where we look.

## Leaks get found, not topped up

Adding refrigerant to a system that lost it puts the same fault back in
service with a clock on it, and every recharge introduces another opportunity
for moisture to get in — which is its own failure mode, because moisture in a
sealed system produces a restriction that behaves nothing like a leak. When we
open a system we locate the leak, replace the filter drier, pull a proper
vacuum, and charge by weight.

Coastal units have one leak location worth naming: the condenser itself.
Corrosion that has gone past the fins and into the tubing does not get repaired
in place, and a condenser that has failed that way on the coast usually means
the rest of the loop has had the same exposure.

## When the honest answer is no

Some of these repairs should not be done. A twenty-five-year-old cabinet with a
failed compressor, a corroded condenser and a discontinued control board is a
conversation about replacement, not a parts order, and we would rather have it
before the work than after. We will not open a sealed system on a unit we do
not expect to survive it, and we will tell you plainly when that is where we
have landed.

When it is worth doing — and on a well-kept built-in with one clear fault, it
often is — it comes with a written estimate first, the flat diagnostic credited
toward the work, genuine OEM parts, 90 days on labour and 365 days on parts.

---

**Contact.** Marsh Tide Appliance Service, Ponte Vedra Beach, FL 32082. Phone (904) 822-9883. Monday – Friday 8:00am – 6:00pm; Saturday 9:00am – 4:00pm; Sunday Closed. The phone is the only channel — this site publishes no contact form and no email intake.

**Affiliation.** Marsh Tide Appliance Service is an independent appliance repair company. We are not affiliated with, authorized by, or endorsed by Sub-Zero or its parent company. All brand names and model numbers are the property of their respective owners and are used only to identify the appliances we service.